- 1. A Proportional Controller is used for
controlling temperature in melting process. Temperature set point is 750°C and temperature measuring tool range is 0 - 1000°C . Proportional
space is set at 15%. Pressure output range from controller is 20–100kN/m2 and pressure output rises when temperature
increases. If pressure output is set at
60 kN/m2 for temperature set point,
find
i. Temperature for pressure output at 20kN/m2ii. Temperature for pressure output at 100kN/m22. In a process,a Proportional Controller is used to control the liquid level in the boiler. The level is set at 8 meters and the level range is 1 to 14 meters. Proportional band is at 20%. The output current has a range of 5–20mA. Determine:-i. The output level when current is 5 mA.ii. The output current at a level of 10 meters.3. An air to open valve on the inflow controls level in a tank. When the process is at the set point the valve opening is 50%. An increase in outflow results in the valve opening increasing to a new steady state value of 80%. What is resulting offset if the controller PB is:i) 80%ii) 40%.4. A temperature controller has the following characteristic curve below:
The controller has a range of 100 0C to 400 0C. The set‐point is 250 0C. Calculate:
i. The controller Proportional Bandii. The controller Proportional Gain